general@tekab.com.
Thursday, November 21st, 2024
Type | : |
|
||
Specification | : | to IEC 60708 |
Conductor | : | Annealed bare solid copper |
Insulation | : | Solid, cellular or form-skin polyolefin material |
Identification | : | Colour coded (refer to technical section) |
Twisting | : | Two conductors are twisted into pair |
Stranding | : | In sub-units of 5 or 10 pairs in units for 50 or 100 pairs, and units of 50 or 100 pairs for more than 100 pairs |
Longitudinal watertightness | : | by filling the interstices of the cores with petroleum jelly compound |
Moisture barrier | : | Screen of longitudinally applied smooth copolymer coated aluminium tape |
Inner Sheath | : | Black PE |
Armour | : | Double steel tape helically applied |
Sheath | : | Black weather resistant PE |
Dielectric strength | : | 500V |
Min. Insulation Resistance at at 200C | : | 1500M Ohm.km |
Max Individual Mutual Capacitance | : | 64 nF/km |
Max Average Mutual Capacitance for cables more than or equal to 20 pairs | : | 56 nF/km |
Max Capacitance unbalance at 800 Hz per 500m length of cable | : | 275pF |
Max Conductor Loop Resistance at 200C | : | 191.8 Ohm/km |
Number of pairs | 10 | 20 | 30 | 50 | 70 | 100 | 150 | 200 | 300 | 400 | 500 | 600 | 800 | 900 | 1000 |
OD (mm, approx) | 14 | 15 | 18 | 20 | 23 | 25 | 30 | 35 | 40 | 48 | 51 | 55 | 62 | 65 | 70 |
Kg/Km (approx) | 215 | 285 | 355 | 505 | 630 | 825 | 1145 | 1430 | 2540 | 3195 | 3780 | 4395 | 5565 | 6135 | 6685 |
Item Code for Form skin insulation : MSAE -- x 2 x 0.5
Solid PE insulation : ESAE -- x 2 x 0.5
Cellular PE insulation : CSAE -- x 2 x 0.5