general@tekab.com.
Tuesday, October 20th, 2026

| Type | : |
|
||
| Specification | : | to IEC 60708 |
| Conductor | : | Annealed bare solid copper |
| Insulation | : | Solid, cellular or form-skin polyolefin material |
| Identification | : | Colour coded (refer to technical section) |
| Twisting | : | Two conductors are twisted into pair |
| Stranding | : | Sub-units of 5 or 10 pairs in units for 50 or 100 pairs, and units of 50 or 100 pairs for more than 100 pairs |
| Moisture barrier | : | Screen of longitudinally applied smooth copolymer coated aluminium tape |
| Messenger | : | Strand of galvanized steel wires |
| Sheath | : | Black weather resistant PE |
| Dielectric strength | : | 500V |
| Min. Insulation Resistance at at 200C | : | 1500M Ohm.km |
| Max Individual Mutual Capacitance | : | 64 nF/km |
| Max Average Mutual Capacitance for cables more than or equal to 20 pairs | : | 56 nF/km |
| Max Capacitance unbalance at 800 Hz per 500m length of cable | : | 275pF |
| Max Conductor Loop Resistance at 200C | : | 114 Ohm/km |
| Number of pairs | 10 | 20 | 30 | 50 | 70 | 100 | 150 | 200 |
| Msngr(Nrx dia) | 7x1.2 | 7x1.2 | 7x1.2 | 7x1.2 | 7x1.6 | 7x1.6 | 7x1.6 | 7x1.6 |
| OD(mm,approx) | 19x9.8 | 21x12 | 23x14 | 26x17 | 30x19 | 34x23 | 38x28 | 42x31 |
| Kg/Km(approx) | 215 | 300 | 375 | 530 | 750 | 1000 | 1370 | 1740 |
Item Code for Form skin insulation : MSTE -- x 2 x 0.6
Solid PE insulation : ESTE -- x 2 x 0.6
Cellular PE insulation : CSTE -- x 2 x 0.6